The correct use process of hydraulic return oil filter
pageview:54
2023.10.08
The following is the general correct usage process for hydraulic return oil filters:
Installation:
Select the appropriate type and specification of return oil filter according to the requirements of the equipment and system.
Install a return oil filter at an appropriate location in the return oil pipeline. Ensure that the installation position is easy to operate and maintain, and tightly connected to the equipment.
Preparation:
The manufacturer of the return oil filter should ensure that the equipment and system are in a closed state and stop the operation of the hydraulic system before any operation.
Prepare necessary tools and equipment, such as wrenches, sealing rings, cleaning cloths, etc.
Clean the filter:
Before disassembling or replacing the Jiangsu return oil filter, clean the surface and surrounding area of the filter to prevent dirt from entering the system.
Gently wipe the filter housing with a cleaning cloth or compressed air to ensure that there are no attached dust or oil stains.
Disassembly and replacement:
Use appropriate tools to remove the housing of the return oil filter. Some filters may require loosening the bolts or rotating the locking ring.
Carefully remove the old filter element or screen and dispose of it properly. Be aware that the filter element may contain residual oil and avoid direct contact.
Cleaning and maintenance:
Check if there are impurities, deposits, or damaged components inside the filter housing. If necessary, thoroughly clean with cleaning solvent or compressed air.
Replace the filter element or filter screen and ensure that the appropriate model and specification of the filter element is selected that is suitable for the equipment and system requirements.
Ensure that the sealing ring and interface of the filter element are not damaged or loose when installing a new filter element.
Installation and testing:
Reinstall the return oil filter housing onto the equipment and tighten the bolts or locking rings. Ensure that the housing is securely installed and sealed.
Open the oil supply valve of the hydraulic system and check for any oil leaks.
Start the equipment and observe if the return oil filter is working properly. Ensure that the system pressure and flow rate are within the normal range.
Please note that the above steps provide a general usage method for the return oil filter. The specific operating steps may vary depending on the type, specifications, and manufacturer's recommendations of the return oil filter. Therefore, before using the return oil filter, carefully read and understand the operating instructions and manufacturer provided guidelines for the used return oil filter. Follow the manufacturer's recommendations and instructions to ensure the correct use and maintenance of the return oil filter to provide filtration efficiency and system performance.